HELUKABEL | PAAR-TRONIC-CY CABLES, EMC-preferred type, Cu-screened

PAAR-TRONIC-CY signal cable

PAAR-TRONIC-CY signal cable series with PVC material features flame retardant and fire-resistant according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, and IEC 60332-1 standard. The product is applied flexibly in many fields with a shield of tin-plated copper mesh with a coverage ratio of approximately 85%.

Cable structure

  • Bare copper conductor, from 0,5 mm² to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
  • Conductor construction:
  • 0,14 mm² = 18x0,1 mm
  • 0,25 mm² = 14x0,15 mm
  • 0,34 mm² = 7x0,25 mm
  • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3
  • Core identification (pair) to DIN 47100
  • Cores stranded in pairs with optimal lay-length
  • Pairs stranded in layers with optimal lay-length
  • Foil wrapping
  • Drain wire, tinned
  • Tinned copper braided screen, approx. 85% coverage
  • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1
  • Sheath colour grey (RAL 7032) also available in other colours on request
  • with meter marking

Properties

  • Extensively oil resistant, oil-/ chemical resistance - see table technical information
  • The materials used in manufacture are cadmium-free and contain no silicone and are free from substances harmful to the wetting properties of lacquers
PAAR-TRONIC-CY signal cable

Technical data

Special PVC data cables for electronic control adapted to DIN VDE 0812 and 0814

Temperature range

  • flexing -5°C to +80°C
  • fixed installation -30°C to +80°C

Operating peak voltage 350 V (not for heavy current installation purposes)

Test voltage

  • core/core 1200 V
  • core/screen 800 V

Breakdown voltage min. 2400 V

Insulation resistance min. 20 MOhm x km

Plant capacity (approx.-value) at 800 Hz

  • core/core 0,14 mm² = 120 pF/m
  • core/core 0,25 mm² = 150 pF/m
  • core/screen 0,14 mm² = 240 pF/m
  • core/screen 0,25 mm² = 270 pF/m

Inductance approx. 0,65 mH/km

Impedance approx. 78 Ohm

K1-coupling approx. 300 pF/100 m

Coupling resistance max. 250 Ohm/km

Minimum bending radius

  • flexing 10x cable Ø
  • fixed installation 5x cable Ø

Radiation resistance up to 80x106 cJ/kg (up to 80 Mrad)

Application

These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist, and wet rooms but are not suitable for open air. PAAR-TRONIC-CY is well suited for use in areas subject to signal interference. The high level of screening reduces substantially the effects of electrical disturbances from parallel running wiring etc. The copper screening is also often used as an "earth". The twisted pairs conform to favorable crosstalk attenuation values.

EMC = Electromagnetic compatibility

To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.

= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

At HELUKABEL, the products manufactured have undergone many stages of strict inspection and testing to ensure the stability and uniformity of product quality. Therefore, the products that reach customers are the best-finished products, to ensure safety during use and performance of the entire factory.

If you are looking for electrical connection solutions and need specific support and advice on wire characteristics to choose the right one, please contact our engineers for advice.

If you still have any concerns or questions, don't hesitate to reach out to HELUKABEL Vietnam's engineering team promptly for detailed assistance.

HELUKABEL® Vietnam

905, Nguyen Kiem Street, Ward 3, Go Vap District, Ho Chi Minh City 700000, Vietnam

Tel. +84 28 77755578 | info@helukabel.com.vn | www.helukabel.com.vn

Back